Cable Fault Locator

Providing you the best range of 33 kv cable fault locator, lt to ht cable fault locator - underground power cable and 5 kv, 1000 j portable cable fault location system, for laboratory, industrial with effective & timely delivery.

33 kV Cable Fault Locator

Request Callback

Get Latest Price

Product Brochure
Cable TypePower Cable
Max Cable Length20 km
Test Voltage Range0-32 kV
Location MethodTDR, Thumping
Display TypeLCD
Power SourceMains Powered
Phase UsageSingle Phase
Protection DegreeIP54
Interface PortUSB
Country Of OriginIndia

Minimum order quantity: 1 Set

SurGen 32(1000):-
  • For fault location in LT to HT 11 kV & 33 kV cables.
  • Inbuilt DC high voltage testing up to 32 kV.
  • Inbuilt burn down facility (Burning) suitable for high resistance faults.
  • Output current at least 240 mA.
  • Thumping (Surge) up to 32 kV with 1000 Joules energy on 8, 16 & 32 kV ranges for pinpointing the fault.
  • Inbuilt ICM & Decay coupler to connect with Reflectometer for finding distance to the fault.
Technical Data:-
Output Voltage - Output Current (Burning)
0 – 8 kV - At least 240 mA
0 – 16 kV - At least 100 mA
0 – 32 kV - At least 50 mA

Output Energy - 1000 Joules Energy on each range
Supply Voltage - 230 V AC +/- 10%, 50/60Hz
Surge Timing -      5 to 15 sec.
Operating Tem. - 0 to 55 Deg. Celsius

Protection Features:-
  • Zero start interlock
  • Range interlock
  • ON/OFF key switch
  • Automatic discharge
  • Auto OFF in case of power supply break
  • High Voltage ON lamp
  • Over load protection through MCB
  • Emergency stop button
Accessories:-
  • 25-meter-high voltage output cable.
  • 10 meter mains supply cable.
  • 25 meter earthing cable.
  • 1 Nos Discharge rod.
  • 5 meter discharge rod lead.
Reflectometer T-610
  • Pulse Echo (TDR), Impulse current (ICM) & Decay method provided to get the distance to almost all types of faults.
  • 10” Colour LCD display with user friendly interface for easy operation.
  • Wi-Fi for internet connection, Enabling Online support of experts to review and help in difficult fault conditions.
  • Adjustable setting for distance range pulse width, time delay and zoom function.
  • Portable, Microprocessor control, Menu driven, Pulse reflection type, suitable for use in the field.
  • Comparison feature of any 5 graphs for review and analysis to get more accurate results.
  • Velocity of propagation (VOP) control makes it easy to precisely pre-locate faults in cables with different velocity. 
  • Automatic storage of more than 100,000 fault graphs.
Technical Data:-
Power Supply - Rechargeable battery with 230V AC + 10%, 50Hz, Charger.
Pulse Amplitude - 20V & 90V 
Pulse Width - 20 nanosecond to 5 microsecond in Pulse Echo Mode
Range - Up to 160 km
Band Width - 200 MHz
VOP Range (Half) - 50 m / microsecond to 150 m / microsecond
Interface - USB
Operating
temperature - -10 to 55 Deg. C
Weight - 6 Kg (Approx.)
Storage - More than 100,000 graphs in FLT (fault file) in Month: Date: Time format
Digipoint:-
  • Magnetic and Acoustic signal strength through bar graph and digits on LCD.
    Coincidence figure (Time delay method) indicates the relative distance to the fault in milliseconds (ms) on LCD.
  • LCD screen with backlight feature for night.
  • Background noise reduction and noise immunity.
  • Built to withstand rugged field conditions with high grade acoustic and magnetic sensors.
  • Automatic mute feature to activate while in motion (during pick up of receiver).
  • Easy, fast and accurate pinpointing.
Technical Data:-
Power Supply - 12 V DC (AA battery x 8).
Gain - > 100db (Acoustic)
> 100db (Magnetic)
Frequency - 100 Hz to 1.5 Khz (Acoustic)
470 Hz to 10 Khz (Magnetic)
Coincidence
figure range - 0 to 99 milliseconds (mS)
Operation time - 50 hours. (approximate)
Weight - 900 gm (approx.)

LT to HT Cable Fault Locator - Underground Power Cable

Request Callback

Get Latest Price

Product Brochure
Cable TypePower Cable
Max Cable Length10 km
Test Voltage Range0-32 kV
Location MethodTDR, Thumping
Display TypeLCD
Power SourceMains Powered
Phase UsageSingle Phase
Protection DegreeIP54
Interface PortUSB
Country Of OriginIndia

Minimum order quantity: 1 Set

SurGen 32(1000):-
  • For fault location in LT to HT 11 kV & 33 kV cables.
  • Inbuilt DC high voltage testing up to 32 kV.
  • Inbuilt burn down facility (Burning) suitable for high resistance faults.
  • Output current at least 240 mA.
  • Thumping (Surge) up to 32 kV with 1000 Joules energy on 8, 16 & 32 kV ranges for pinpointing the fault.
  • Inbuilt ICM & Decay coupler to connect with Reflectometer for finding distance to the fault.
Technical Data:-
Output Voltage - Output Current (Burning)
0 – 8 kV - At least 240 mA
0 – 16 kV - At least 100 mA
0 – 32 kV - At least 50 mA

Output Energy - 1000 Joules Energy on each range
Supply Voltage - 230 V AC +/- 10%, 50/60Hz
Surge Timing -      5 to 15 sec.
Operating Tem. - 0 to 55 Deg. Celsius

Protection Features:-
  • Zero start interlock
  • Range interlock
  • ON/OFF key switch
  • Automatic discharge
  • Auto OFF in case of power supply break
  • High Voltage ON lamp
  • Over load protection through MCB
  • Emergency stop button
Accessories:-
  • 25-meter-high voltage output cable.
  • 10 meter mains supply cable.
  • 25 meter earthing cable.
  • 1 Nos Discharge rod.
  • 5 meter discharge rod lead.
Reflectometer T-610
  • Pulse Echo (TDR), Impulse current (ICM) & Decay method provided to get the distance to almost all types of faults.
  • 10” Colour LCD display with user friendly interface for easy operation.
  • Wi-Fi for internet connection, Enabling Online support of experts to review and help in difficult fault conditions.
  • Adjustable setting for distance range pulse width, time delay and zoom function.
  • Portable, Microprocessor control, Menu driven, Pulse reflection type, suitable for use in the field.
  • Comparison feature of any 5 graphs for review and analysis to get more accurate results.
  • Velocity of propagation (VOP) control makes it easy to precisely pre-locate faults in cables with different velocity. 
  • Automatic storage of more than 100,000 fault graphs.
Technical Data:-
Power Supply - Rechargeable battery with 230V AC + 10%, 50Hz, Charger.
Pulse Amplitude - 20V & 90V 
Pulse Width - 20 nanosecond to 5 microsecond in Pulse Echo Mode
Range - Up to 160 km
Band Width - 200 MHz
VOP Range (Half) - 50 m / microsecond to 150 m / microsecond
Interface - USB
Operating
temperature - -10 to 55 Deg. C
Weight - 6 Kg (Approx.)
Storage - More than 100,000 graphs in FLT (fault file) in Month: Date: Time format
Digipoint:-
  • Magnetic and Acoustic signal strength through bar graph and digits on LCD.
    Coincidence figure (Time delay method) indicates the relative distance to the fault in milliseconds (ms) on LCD.
  • LCD screen with backlight feature for night.
  • Background noise reduction and noise immunity.
  • Built to withstand rugged field conditions with high grade acoustic and magnetic sensors.
  • Automatic mute feature to activate while in motion (during pick up of receiver).
  • Easy, fast and accurate pinpointing.
Technical Data:-
Power Supply - 12 V DC (AA battery x 8).
Gain - > 100db (Acoustic)
> 100db (Magnetic)
Frequency - 100 Hz to 1.5 Khz (Acoustic)
470 Hz to 10 Khz (Magnetic)
Coincidence
figure range - 0 to 99 milliseconds (mS)
Operation time - 50 hours. (approximate)
Weight - 900 gm (approx.)

5 KV, 1000 J Portable Cable Fault Location System, For Laboratory, Industrial

Request Callback

Get Latest Price

Product Brochure
Cable TypePower Cable
Max Cable Length5 km
Test Voltage Range0-5 kV
Location MethodThumping, TDR
Display TypeTouch Screen
Power SourceMains Powered
Phase UsageSingle Phase
Protection DegreeIP54
Interface PortUSB
Country Of OriginIndia

Minimum order quantity: 1 Set

SurGen 5(1000):-
  • Suitable for fault location in LT cables.
  • Inbuilt DC high voltage testing up to 5 kV.
  • Output current at least 250 mA.
  • Thumping (Surge) up to 5 kV with 1000 Joules energy for pinpointing the fault.
  • Inbuilt ICM coupler to connect with Reflectometer for finding distance to the fault.
  • High voltage metering and mA metering on output.
  • High safety features.

Technical Data

Output Voltage : 0 to 5 kV DC
Output Current : At least 250 mA
Output Energy : 1000 Joules Energy
Supply Voltage : 230 V AC +/- 10%, 50/60Hz
Auto Discharge : Built in
Surge Timing : Manual mode or 5 to 15 sec in Auto mode
Signal Output : To work with Reflectometer
Operating
Temperature : 0 to 55 Deg. Celsius
Storage
Temperature : -10 to 60 Deg. Celsius

Protection Features:-
  • Zero start interlock
  • ON/OFF key switch.
  • Automatic discharge
  • Auto OFF in case of power supply break
  • High Voltage ON lamp
  • Emergency stop button.
  • Over load protection through MCB
Accessories Included:-
  • 15-meter-high voltage output cable
  • 10 meter mains supply cable.
  • 15 meter earthing cable.
  • 1 Nos Discharge rod.
  • 5-meter discharge rod lead.

Digipoint:-
  • Magnetic and Acoustic signal strength through bar graph and digits on LCD.
  • Coincidence figure (Time delay method) indicates the relative distance to the fault in milliseconds (ms) on LCD.
  • LCD screen with backlight feature for night.
  • Background noise reduction and noise immunity.
  • Built to withstand rugged field conditions with high grade acoustic and magnetic sensors.
  • Automatic mute feature to activate while in motion (during pick up of receiver)
  • Easy, fast and accurate pinpointing.

Reflectometer T-610(L):-
  • Pulse Echo (TDR), Impulse current (ICM) & Decay method provided to get the distance to almost all types of faults.
  • 10” Colour LCD display with user friendly interface for easy operation.
  • Wi-Fi for internet connection, Enabling Online support of experts to review and help in difficult fault conditions.
  • Adjustable setting for distance range pulse width, time delay and zoom function.
  • Portable, Microprocessor control, Menu driven, Pulse reflection type, suitable for use in the field.
  • Comparison feature of any 5 graphs for review and analysis to get more accurate results.
  • Velocity of propagation (VOP) control makes it easy to precisely pre-locate faults in cables with different velocity.
  • Automatic storage of more than 100,000 fault graphs.
X

Contact Us

Mr. Ravi Gupta (Director)
Techno Instrumentation (India) Pvt. Ltd.
Street No.1 - B, Plot No. 67, Friends Colony Industrial Area, Behind Mansarovar Park Metro Station, G. T. Road Shahdara
New Delhi - 110095, Delhi, India

Get Directions
Send Email
Share: