Inbuilt DC high voltage testing, which can be used to do pressure testing(Hipot test) of the cables to find out which phase is faulty along with its breakdown voltage and leakage current.
High voltage surge generation(Thumping), which helps in finding the distance to the fault and pinpointing the fault point.
Inbuilt Burning facility, which is an integral part of Surge Generator. In the case of high resistance faults, burning is required for easy pre-location and pinpointing of the fault.
Product Details:
Minimum Order Quantity | 1 Set |
Model Name/Number | SurGen 5(1000), Digipoint, Reflectometer T-610 |
Packaging Type | Wooden Box |
Brand | Techno Instrumentation (India) Pvt Ltd |
I Deal In | New Only |
Body Material | Aluminium |
Dimensions | 500x 500 x 700 MM (LWH) |
Country of Origin | Made in India |
SurGen 5(1000)
Inbuilt Pressure Testing (Hi-pot Test)
Perform DC high voltage testing up to 5 kV to find out which phase is faulty and determine its breakdown voltage and the leakage current.
Digipoint
Coincidence Figure
Pinpointing the exact location of faults in cables which are laid inside pipe is very difficult because the air inside the pipe will lead to echo of sound which is generated at the fault point, leading to sound/acoustic signal of strength similar to the fault point at different parts of the cable, hence to pinpoint the exact location of fault in these conditions we use the coincidence feature of the Digipoint, which gives the distance to the fault in milliseconds with respect to your position.
Reflectometer T-610
Additional Information: