Power Cable Fault Locator

We manufacture the complete range of power cable fault locating instruments.
  • LT Cable fault locator.
  • LT to 11 kV Cable fault locator.
  • LT to 33 kV Cable fault locator.
  • LT to HT Cable fault locator.

HT Cable Fault Locator

HT Cable Fault Locator
  • HT Cable Fault Locator
  • HT Cable Fault Locator
  • HT Cable Fault Locator
  • HT Cable Fault Locator
  • HT Cable Fault Locator
  • HT Cable Fault Locator
  • HT Cable Fault Locator
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Minimum Order Quantity1 Set
Voltage33 kV
BrandTechno Instrumentation (India) Pvt Ltd
Dimension580 x 580 x 780 MM (LWH)
Model Name/NumberSurGen 32(R2000), Digipoint, Reflectometer T-710
Operation Temperature0 Degree to 55 Degree C
Weight Gram170 KG
Arc ReflectionARC Reflection Filter inbuilt in Surge Unit
Body MaterialAluminium
Country of OriginMade in India

SurGen 32(R2000) 

  • For fault location in LT to HT 11 kV & 33 kV cables.
  • Inbuilt DC high voltage testing up to 32 kV.
  • Inbuilt burn down facility (Burning) suitable for high resistance faults. 
  • Output current more than 350 mA 
  • Thumping (Surge) up to 32 kV with 2000 Joules energy on 8, 16 & 32 kV ranges for pinpointing the fault. 
  • Inbuilt ARC Reflection filter, ICM & Decay coupler to connect with Reflectometer for finding distance to the fault.
  • High voltage metering and mA metering on output.
  • High safety features. 

Digipoint

  • Magnetic and Acoustic signal strength through bar graph and digits on LCD.
  • Coincidence figure (Time delay method) indicates the relative distance to the fault in milliseconds (ms) on LCD.
  • LCD screen with backlight feature for night.
  • Automatic mute feature to activate while in motion (during pick up of receiver).

Reflectometer T-710

  • Pulse Echo (TDR), Impulse current (ICM), ARC Reflection & Decay method provided to get the distance to almost all types of faults.
  • 10” Colour LCD display with user friendly interface for easy operation.
  • Adjustable setting for distance range pulse width, time delay and zoom function.
  • Portable, Microprocessor control, Menu driven, Pulse reflection type, suitable for use in the field.
  • Comparison feature of any 5 graphs for review and analysis to get more accurate results.
  • Automatic storage of more than 100,000 fault graphs.
  • Rechargeable battery with 230V AC + 10%, 50Hz, Charger.
Request
Callback


Additional Information:

  • Production Capacity: 4 Set per month
  • Delivery Time: Within 4 to 6 Weeks
  • Packaging Details: Wooden Box Packing
Yes! I am Interested

Underground Electrical Cable Fault Locator

Underground Electrical Cable Fault Locator
  • Underground Electrical Cable Fault Locator
  • Underground Electrical Cable Fault Locator
  • Underground Electrical Cable Fault Locator
  • Underground Electrical Cable Fault Locator
  • Underground Electrical Cable Fault Locator
  • Underground Electrical Cable Fault Locator
  • Underground Electrical Cable Fault Locator
  • Underground Electrical Cable Fault Locator
  • Underground Electrical Cable Fault Locator
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Minimum Order Quantity1 Set
Voltage33 kV
TypeIndustrial Relay
BrandTechno Instrumentation (India) Pvt. Ltd.
Dimension520 X 520 X 730 (LBH)
Model Name/NumberSurGen 32(1000), Reflectometer T-610 & Digipoint
Operation Temperature0 deg. to 55 deg. Celsicus
Country of OriginMade in India

SurGen 32(1000) 

  • For fault location in LT to HT 11 kV & 33 kV cables.
  • Inbuilt DC high voltage testing up to 32 kV.
  • Inbuilt burn down facility (Burning) suitable for high resistance faults.
  • Output current more than 240 mA.
  • Thumping (Surge) up to 32 kV with 1000 Joules energy on 8, 16 & 32 kV ranges for pinpointing the fault. 
  • Inbuilt ICM & Decay coupler to connect with Reflectometer for finding distance to the fault. 
  • High voltage metering and mA metering on output.
  • High safety features.

Inbuilt Pressure Testing (Hi-pot Test)
Perform DC high voltage testing up to 32 kV to find out which phase is faulty and determine its breakdown voltage and the leakage current.
Inbuilt Burn down facility
In case of high resistive faults, burning is required. Burning will reduce the breakdown voltage of the fault and it will be easy to pre-locate and pinpoint. Hence, burning facility of more than 240 mA is provided.

Digipoint

  • Magnetic and Acoustic signal strength through bar graph and digits on LCD. 
  • Coincidence figure (Time delay method) indicates the relative distance to the fault in milliseconds (ms) on LCD.
  • LCD screen with backlight feature for night.
  • Background noise reduction and noise immunity.
  • Built to withstand rugged field conditions with high grade acoustic and magnetic sensors.
  • Automatic mute feature to activate while in motion (during pick up of receiver).
  • Easy, fast and accurate pinpointing

Coincidence Figure
Pinpointing the exact location of faults in cables which are laid inside pipe is very difficult because the air inside the pipe will lead to echo of sound which is generated at the fault point, leading to sound/acoustic signal of strength similar to the fault point at different parts of the cable, hence to pinpoint the exact location of fault in these conditions we use the coincidence feature of the Digipoint, which gives the distance to the fault in milliseconds with respect to your position.

Reflectometer T-610

  • Pulse Echo (TDR), Impulse current (ICM) & Decay method provided to get the distance to almost all types of faults.
  • 10” Colour LCD display with user friendly interface for easy operation.
  • Adjustable setting for distance range pulse width, time delay and zoom function.
  • Portable, Microprocessor control, Menu driven, Pulse reflection type, suitable for use in the field.
  • Comparison feature of any 5 graphs for review and analysis to get more accurate results.
  • Velocity of propagation (VOP) control makes it easy to precisely pre-locate faults in cables with different velocity.
  • Automatic storage of more than 100,000 fault graphs.
Request
Callback


Additional Information:

  • Production Capacity: 5 Set per month
  • Delivery Time: Within 4 to 6 weeks
  • Packaging Details: Wooden Packing
Yes! I am Interested

1 Introduction To Cable Fault Locating

1 Introduction To Cable Fault Locating
  • 1 Introduction To Cable Fault Locating
  • 1 Introduction To Cable Fault Locating
  • 1 Introduction To Cable Fault Locating
  • 1 Introduction To Cable Fault Locating
  • 1 Introduction To Cable Fault Locating
  • 1 Introduction To Cable Fault Locating
  • 1 Introduction To Cable Fault Locating
  • 1 Introduction To Cable Fault Locating
  • 1 Introduction To Cable Fault Locating
  • 1 Introduction To Cable Fault Locating
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Minimum Order Quantity1 Set
Voltage33 kV
BrandTechno Instrumentation (India) Pvt Ltd
Dimension520MM(140MM Handle) X 520MM(130MM Handle) X 730MM(70MM Wheel + 70MM Handle) (LBH)
Model Name/NumberSurGen 32(1000), Digipoint, Reflectometer T-610
Weight Gram120KG Approx.
Operation Temperature0 Degree to 55 Degree C
Body MaterialAluminium
Country of OriginMade in India

SurGen 32(1000) 

  • For fault location in LT to HT 11 kV & 33 kV cables.
  • Inbuilt DC high voltage testing up to 32 kV.
  • Inbuilt burn down facility (Burning) suitable for high resistance faults.
  • Output current more than 240 mA.
  • Thumping (Surge) up to 32 kV with 1000 Joules energy on 8, 16 & 32 kV ranges for pinpointing the fault. 
  • Inbuilt ICM & Decay coupler to connect with Reflectometer for finding distance to the fault. 
  • High voltage metering and mA metering on output.
  • High safety features.

Inbuilt Pressure Testing (Hi-pot Test)
Perform DC high voltage testing up to 32 kV to find out which phase is faulty and determine its breakdown voltage and the leakage current.
Inbuilt Burn down facility
In case of high resistive faults, burning is required. Burning will reduce the breakdown voltage of the fault and it will be easy to pre-locate and pinpoint. Hence, burning facility of more than 240 mA is provided.

Digipoint

  • Magnetic and Acoustic signal strength through bar graph and digits on LCD. 
  • Coincidence figure (Time delay method) indicates the relative distance to the fault in milliseconds (ms) on LCD.
  • LCD screen with backlight feature for night.
  • Background noise reduction and noise immunity.
  • Built to withstand rugged field conditions with high grade acoustic and magnetic sensors.
  • Automatic mute feature to activate while in motion (during pick up of receiver).
  • Easy, fast and accurate pinpointing

Coincidence Figure
Pinpointing the exact location of faults in cables which are laid inside pipe is very difficult because the air inside the pipe will lead to echo of sound which is generated at the fault point, leading to sound/acoustic signal of strength similar to the fault point at different parts of the cable, hence to pinpoint the exact location of fault in these conditions we use the coincidence feature of the Digipoint, which gives the distance to the fault in milliseconds with respect to your position.

Reflectometer T-610

  • Pulse Echo (TDR), Impulse current (ICM) & Decay method provided to get the distance to almost all types of faults.
  • 10” Colour LCD display with user friendly interface for easy operation.
  • Adjustable setting for distance range pulse width, time delay and zoom function.
  • Portable, Microprocessor control, Menu driven, Pulse reflection type, suitable for use in the field.
  • Comparison feature of any 5 graphs for review and analysis to get more accurate results.
  • Velocity of propagation (VOP) control makes it easy to precisely pre-locate faults in cables with different velocity.
  • Automatic storage of more than 100,000 fault graphs.
Request
Callback


Additional Information:

  • Production Capacity: 6 Set per month
  • Delivery Time: Within 4 to 6 Weeks
  • Packaging Details: Wooden Box Packing
Yes! I am Interested

LT to HT Cable Fault Locator, Fault Locator Manufacturer

LT to HT Cable Fault Locator, Fault Locator Manufacturer
  • LT to HT Cable Fault Locator, Fault Locator Manufacturer
  • LT to HT Cable Fault Locator, Fault Locator Manufacturer
  • LT to HT Cable Fault Locator, Fault Locator Manufacturer
  • LT to HT Cable Fault Locator, Fault Locator Manufacturer
  • LT to HT Cable Fault Locator, Fault Locator Manufacturer
  • LT to HT Cable Fault Locator, Fault Locator Manufacturer
  • LT to HT Cable Fault Locator, Fault Locator Manufacturer
  • LT to HT Cable Fault Locator, Fault Locator Manufacturer
  • LT to HT Cable Fault Locator, Fault Locator Manufacturer
  • LT to HT Cable Fault Locator, Fault Locator Manufacturer
  • LT to HT Cable Fault Locator, Fault Locator Manufacturer
  • LT to HT Cable Fault Locator, Fault Locator Manufacturer
  • LT to HT Cable Fault Locator, Fault Locator Manufacturer
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Minimum Order Quantity1 Set
Voltage33 kV
BrandTechno Instrumentation (India) Pvt Ltd
Dimension580 x 580 x 780 MM (LWH)
Model Name/NumberSurGen 32(2000), Digipoint, Reflectometer T-610
Operation Temperature0 Degree to 55 Degree C
Weight Gram148KG
Body MaterialAluminium
Country of OriginMade in India

SurGen 32(2000) 

  • For fault location in LT to HT 11 kV & 33 kV cables.
  • Inbuilt DC high voltage testing up to 32 kV.
  • Inbuilt burn down facility (Burning) suitable for high resistance faults.
  • Output current more than 350 mA.
  • Thumping (Surge) up to 32 kV with 2000 Joules energy on 8, 16 & 32 kV ranges for pinpointing the fault. 
  • Inbuilt ICM & Decay coupler to connect with Reflectometer for finding distance to the fault. 
  • High voltage metering and mA metering on output.
  • High safety features.

Inbuilt Pressure Testing (Hi-pot Test)
Perform DC high voltage testing up to 32 kV to find out which phase is faulty and determine its breakdown voltage and the leakage current.
Inbuilt Burn down facility
In case of high resistive faults, burning is required. Burning will reduce the breakdown voltage of the fault and it will be easy to pre-locate and pinpoint. Hence, burning facility of more than 350 mA is provided.

Digipoint

  • Magnetic and Acoustic signal strength through bar graph and digits on LCD. 
  • Coincidence figure (Time delay method) indicates the relative distance to the fault in milliseconds (ms) on LCD.
  • LCD screen with backlight feature for night.
  • Background noise reduction and noise immunity.
  • Built to withstand rugged field conditions with high grade acoustic and magnetic sensors.
  • Automatic mute feature to activate while in motion (during pick up of receiver).
  • Easy, fast and accurate pinpointing

Coincidence Figure
Pinpointing the exact location of faults in cables which are laid inside pipe is very difficult because the air inside the pipe will lead to echo of sound which is generated at the fault point, leading to sound/acoustic signal of strength similar to the fault point at different parts of the cable, hence to pinpoint the exact location of fault in these conditions we use the coincidence feature of the Digipoint, which gives the distance to the fault in milliseconds with respect to your position.

Reflectometer T-610

  • Pulse Echo (TDR), Impulse current (ICM) & Decay method provided to get the distance to almost all types of faults.
  • 10” Colour LCD display with user friendly interface for easy operation.
  • Adjustable setting for distance range pulse width, time delay and zoom function.
  • Portable, Microprocessor control, Menu driven, Pulse reflection type, suitable for use in the field.
  • Comparison feature of any 5 graphs for review and analysis to get more accurate results.
  • Velocity of propagation (VOP) control makes it easy to precisely pre-locate faults in cables with different velocity.
  • Automatic storage of more than 100,000 fault graphs.
Request
Callback


Additional Information:

  • Production Capacity: 4 Set per month
  • Delivery Time: 4 to 6 Weeks
  • Packaging Details: Wooden Box Packing
Yes! I am Interested

32kV HT/LT Underground Cable Fault Locating System

32kV HT/LT Underground Cable Fault Locating System
  • 32kV HT/LT Underground Cable Fault Locating System
  • 32kV HT/LT Underground Cable Fault Locating System
  • 32kV HT/LT Underground Cable Fault Locating System
  • 32kV HT/LT Underground Cable Fault Locating System
  • 32kV HT/LT Underground Cable Fault Locating System
  • 32kV HT/LT Underground Cable Fault Locating System
  • 32kV HT/LT Underground Cable Fault Locating System
  • 32kV HT/LT Underground Cable Fault Locating System
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Minimum Order Quantity1 Set
Voltage33 kV
BrandTechno Instrumentation (India) Pvt. Ltd.
Dimension580x580x780MM(LxBxH)
Model Name/NumberSurGen 32(1500), Reflectometer T-610, Digipoint
Weight Gram150 KG
Operation Temperature0 to 55 Degree Celsius
Country of OriginMade in India

SurGen 32(1500) 
  • For fault location in LT to HT 11 kV & 33 kV cables.
  • Inbuilt DC high voltage testing up to 32 kV.
  • Inbuilt burn down facility (Burning) suitable for high resistance faults.
  • Output current more than 280 mA.
  • Thumping (Surge) up to 32 kV with 1500 Joules energy on 8, 16 & 32 kV ranges for pinpointing the fault. 
  • Inbuilt ICM & Decay coupler to connect with Reflectometer for finding distance to the fault. 
  • High voltage metering and mA metering on output.
  • High safety features.
Inbuilt Pressure Testing (Hi-pot Test)
Perform DC high voltage testing up to 32 kV to find out which phase is faulty and determine its breakdown voltage and the leakage current.
Inbuilt Burn down facility
In case of high resistive faults, burning is required. Burning will reduce the breakdown voltage of the fault and it will be easy to pre-locate and pinpoint. Hence, burning facility of more than 280 mA is provided.

Digipoint
  • Magnetic and Acoustic signal strength through bar graph and digits on LCD. 
  • Coincidence figure (Time delay method) indicates the relative distance to the fault in milliseconds (ms) on LCD.
  • LCD screen with backlight feature for night.
  • Background noise reduction and noise immunity.
  • Built to withstand rugged field conditions with high grade acoustic and magnetic sensors.
  • Automatic mute feature to activate while in motion (during pick up of receiver).
  • Easy, fast and accurate pinpointing
Coincidence Figure
Pinpointing the exact location of faults in cables which are laid inside pipe is very difficult because the air inside the pipe will lead to echo of sound which is generated at the fault point, leading to sound/acoustic signal of strength similar to the fault point at different parts of the cable, hence to pinpoint the exact location of fault in these conditions we use the coincidence feature of the Digipoint, which gives the distance to the fault in milliseconds with respect to your position.

Reflectometer T-610
  • Pulse Echo (TDR), Impulse current (ICM) & Decay method provided to get the distance to almost all types of faults.
  • 10” Colour LCD display with user friendly interface for easy operation.
  • Adjustable setting for distance range pulse width, time delay and zoom function.
  • Portable, Microprocessor control, Menu driven, Pulse reflection type, suitable for use in the field.
  • Comparison feature of any 5 graphs for review and analysis to get more accurate results.
  • Velocity of propagation (VOP) control makes it easy to precisely pre-locate faults in cables with different velocity.
  • Automatic storage of more than 100,000 fault graphs.
Request
Callback


Additional Information:

  • Production Capacity: 4 set per month
  • Delivery Time: 4 to 6 weeks
  • Packaging Details: Wooden Packing
Yes! I am Interested

LT Cable Fault Locator

LT Cable Fault Locator
  • LT Cable Fault Locator
  • LT Cable Fault Locator
  • LT Cable Fault Locator
  • LT Cable Fault Locator
  • LT Cable Fault Locator
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Minimum Order Quantity1 Set
Voltage3 kV
BrandTechno Instrumentation (India) Pvt Ltd
Dimension500 x 500x 700MM (LWH)
Model Name/NumberSurGen 5(1000), Digipoint, Reflectometer T-610
Weight Gram85 KG Approx.
Operation Temperature0 Degree to 55 Degree C
Body MaterialAluminium
Country of OriginMade in India

SurGen 5(1000) 

  • For fault location in LT cables.
  • Inbuilt DC high voltage testing up to 5 kV.
  • Output current more than 250 mA.
  • Thumping (Surge) up to 5 kV with 1000 Joules energy for pinpointing the fault. 
  • Inbuilt ICM coupler to connect with Reflectometer for finding distance to the fault.
  • High voltage metering and mA metering on output.
  • High safety features.

Inbuilt Pressure Testing (Hi-pot Test)
Perform DC high voltage testing up to 5 kV to find out which phase is faulty and determine its breakdown voltage and the leakage current.


Digipoint

  • Magnetic and Acoustic signal strength through bar graph and digits on LCD. 
  • Coincidence figure (Time delay method) indicates the relative distance to the fault in milliseconds (ms) on LCD.
  • LCD screen with backlight feature for night.
  • Background noise reduction and noise immunity.
  • Built to withstand rugged field conditions with high grade acoustic and magnetic sensors.
  • Automatic mute feature to activate while in motion (during pick up of receiver).
  • Easy, fast and accurate pinpointing

Coincidence Figure
Pinpointing the exact location of faults in cables which are laid inside pipe is very difficult because the air inside the pipe will lead to echo of sound which is generated at the fault point, leading to sound/acoustic signal of strength similar to the fault point at different parts of the cable, hence to pinpoint the exact location of fault in these conditions we use the coincidence feature of the Digipoint, which gives the distance to the fault in milliseconds with respect to your position.

 


Reflectometer T-610

  • Pulse Echo (TDR), Impulse current (ICM) & Decay method provided to get the distance to almost all types of faults.
  • 10” Colour LCD display with user friendly interface for easy operation.
  • Adjustable setting for distance range pulse width, time delay and zoom function.
  • Portable, Microprocessor control, Menu driven, Pulse reflection type, suitable for use in the field.
  • Comparison feature of any 5 graphs for review and analysis to get more accurate results.
  • Velocity of propagation (VOP) control makes it easy to precisely pre-locate faults in cables with different velocity.
  • Automatic storage of more than 100,000 fault graphs.
Request
Callback


Additional Information:

  • Production Capacity: 6 Set per month
  • Delivery Time: Within 4 to 6 Weeks
  • Packaging Details: Wooden Box Packing
Yes! I am Interested

Cable Fault Locator Surge Generator

Cable Fault Locator Surge Generator
  • Cable Fault Locator Surge Generator
  • Cable Fault Locator Surge Generator
  • Cable Fault Locator Surge Generator
  • Cable Fault Locator Surge Generator
  • Cable Fault Locator Surge Generator
  • Cable Fault Locator Surge Generator
  • Cable Fault Locator Surge Generator
  • Cable Fault Locator Surge Generator
  • Cable Fault Locator Surge Generator
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Minimum Order Quantity1 Set
Voltage33 kV
BrandTechno Instrumentation (India) Pvt Ltd
Dimension580 x 580 x 780 MM (LWH)
Model Name/NumberSurGen 32(1500), Digipoint, Reflectometer T-610
Weight Gram147 KG Approx.
Operation Temperature0 Degree to 55 Degree C
Body MaterialAluminium
Country of OriginMade in India

SurGen 32(1500) 

  • For fault location in LT to HT 11 kV & 33 kV cables.
  • Inbuilt DC high voltage testing up to 32 kV.
  • Inbuilt burn down facility (Burning) suitable for high resistance faults.
  • Output current more than 280 mA.
  • Thumping (Surge) up to 32 kV with 1500 Joules energy on 8, 16 & 32 kV ranges for pinpointing the fault. 
  • Inbuilt ICM & Decay coupler to connect with Reflectometer for finding distance to the fault. 
  • High voltage metering and mA metering on output.
  • High safety features.

Inbuilt Pressure Testing (Hi-pot Test)
Perform DC high voltage testing up to 32 kV to find out which phase is faulty and determine its breakdown voltage and the leakage current.
Inbuilt Burn down facility
In case of high resistive faults, burning is required. Burning will reduce the breakdown voltage of the fault and it will be easy to pre-locate and pinpoint. Hence, burning facility of more than 280 mA is provided.


Digipoint

  • Magnetic and Acoustic signal strength through bar graph and digits on LCD. 
  • Coincidence figure (Time delay method) indicates the relative distance to the fault in milliseconds (ms) on LCD.
  • LCD screen with backlight feature for night.
  • Background noise reduction and noise immunity.
  • Built to withstand rugged field conditions with high grade acoustic and magnetic sensors.
  • Automatic mute feature to activate while in motion (during pick up of receiver).
  • Easy, fast and accurate pinpointing

Coincidence Figure
Pinpointing the exact location of faults in cables which are laid inside pipe is very difficult because the air inside the pipe will lead to echo of sound which is generated at the fault point, leading to sound/acoustic signal of strength similar to the fault point at different parts of the cable, hence to pinpoint the exact location of fault in these conditions we use the coincidence feature of the Digipoint, which gives the distance to the fault in milliseconds with respect to your position.

Reflectometer T-610

  • Pulse Echo (TDR), Impulse current (ICM) & Decay method provided to get the distance to almost all types of faults.
  • 10” Colour LCD display with user friendly interface for easy operation.
  • Adjustable setting for distance range pulse width, time delay and zoom function.
  • Portable, Microprocessor control, Menu driven, Pulse reflection type, suitable for use in the field.
  • Comparison feature of any 5 graphs for review and analysis to get more accurate results.
  • Velocity of propagation (VOP) control makes it easy to precisely pre-locate faults in cables with different velocity.
  • Automatic storage of more than 100,000 fault graphs.

 

Request
Callback


Additional Information:

  • Production Capacity: 4 Set per month
  • Delivery Time: Within 4 to 6 Weeks
  • Packaging Details: Wooden Box Packing
Yes! I am Interested
X

Product Videos

Explore More Products

View All Products




Reach Us
Mr. Ravi Gupta (Director)
Techno Instrumentation (India) Pvt. Ltd.
Plot No. 67, Street No. 1B, Friends Colony, Industrial Area, G. T. Road, Shahdara
Delhi - 110095, India
Get Directions


Call Us


Send E-mail