Underground Cable Fault Locators

Complete range of underground cable fault locators. Manufactured in India.
  • Surge Generators
  • Reflectometer(Pre-locator) - Cable fault distance locator
  • Cable fault finder/pinpointer
  • High Voltage Murray Loop
  • DC high voltage testers
  • Cable fault locating van

Cable Fault Locators, For Industrial And Laboratory

Cable Fault Locators, For Industrial And Laboratory
  • Cable Fault Locators, For Industrial And Laboratory
  • Cable Fault Locators, For Industrial And Laboratory
  • Cable Fault Locators, For Industrial And Laboratory
  • Cable Fault Locators, For Industrial And Laboratory
  • Cable Fault Locators, For Industrial And Laboratory
  • Cable Fault Locators, For Industrial And Laboratory
  • Cable Fault Locators, For Industrial And Laboratory
  • Cable Fault Locators, For Industrial And Laboratory
  • Cable Fault Locators, For Industrial And Laboratory
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Minimum Order Quantity1 Set
Voltage33 kV
BrandTechno Instrumentation (India) Pvt Ltd
Dimension580 x 580 x 780 MM (LWH)
Model Name/NumberSurGen 32(1500), Digipoint, Reflectometer T-610
Weight Gram147KG
Operation Temperature0 Degree to 55 Degree C
Body MaterialAluminium
Country of OriginMade in India

SurGen 32(1500) 

  • For fault location in LT to HT 11 kV & 33 kV cables.
  • Inbuilt DC high voltage testing up to 32 kV.
  • Inbuilt burn down facility (Burning) suitable for high resistance faults.
  • Output current more than 280 mA.
  • Thumping (Surge) up to 32 kV with 1500 Joules energy on 8, 16 & 32 kV ranges for pinpointing the fault. 
  • Inbuilt ICM & Decay coupler to connect with Reflectometer for finding distance to the fault. 
  • High voltage metering and mA metering on output.
  • High safety features.

Inbuilt Pressure Testing (Hi-pot Test)
Perform DC high voltage testing up to 32 kV to find out which phase is faulty and determine its breakdown voltage and the leakage current.
Inbuilt Burn down facility
In case of high resistive faults, burning is required. Burning will reduce the breakdown voltage of the fault and it will be easy to pre-locate and pinpoint. Hence, burning facility of more than 280 mA is provided.


Digipoint

  • Magnetic and Acoustic signal strength through bar graph and digits on LCD. 
  • Coincidence figure (Time delay method) indicates the relative distance to the fault in milliseconds (ms) on LCD.
  • LCD screen with backlight feature for night.
  • Background noise reduction and noise immunity.
  • Built to withstand rugged field conditions with high grade acoustic and magnetic sensors.
  • Automatic mute feature to activate while in motion (during pick up of receiver).
  • Easy, fast and accurate pinpointing

Coincidence Figure
Pinpointing the exact location of faults in cables which are laid inside pipe is very difficult because the air inside the pipe will lead to echo of sound which is generated at the fault point, leading to sound/acoustic signal of strength similar to the fault point at different parts of the cable, hence to pinpoint the exact location of fault in these conditions we use the coincidence feature of the Digipoint, which gives the distance to the fault in milliseconds with respect to your position.

Reflectometer T-610

  • Pulse Echo (TDR), Impulse current (ICM) & Decay method provided to get the distance to almost all types of faults.
  • 10” Colour LCD display with user friendly interface for easy operation.
  • Adjustable setting for distance range pulse width, time delay and zoom function.
  • Portable, Microprocessor control, Menu driven, Pulse reflection type, suitable for use in the field.
  • Comparison feature of any 5 graphs for review and analysis to get more accurate results.
  • Velocity of propagation (VOP) control makes it easy to precisely pre-locate faults in cables with different velocity.
  • Automatic storage of more than 100,000 fault graphs.
Request
Callback


Additional Information:

  • Production Capacity: 6 Set per month
  • Delivery Time: Within 4 to 6 Weeks
  • Packaging Details: Wooden Box Packing
Yes! I am Interested

33kv Cable Fault Locator

33kv Cable Fault Locator
  • 33kv Cable Fault Locator
  • 33kv Cable Fault Locator
  • 33kv Cable Fault Locator
  • 33kv Cable Fault Locator
  • 33kv Cable Fault Locator
  • 33kv Cable Fault Locator
  • 33kv Cable Fault Locator
  • 33kv Cable Fault Locator
  • 33kv Cable Fault Locator
  • 33kv Cable Fault Locator
  • 33kv Cable Fault Locator
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Minimum Order Quantity1 Set
Voltage33 kV
BrandTechno Instrumentation (India) Pvt Ltd
Dimension520MM(140MM Handle) X 520MM(130MM Handle) X 730MM(70MM Wheel + 70MM Handle) (LBH)
Model Name/NumberSurGen 32(1000), Digipoint, Reflectometer T-610
Operation Temperature0 Degree to 55 Degree C
Weight Gram120KG Approx.
Country of OriginMade in India

SurGen 32(1000) 

  • For fault location in LT to HT 11 kV & 33 kV cables.
  • Inbuilt DC high voltage testing up to 32 kV.
  • Inbuilt burn down facility (Burning) suitable for high resistance faults.
  • Output current more than 240 mA.
  • Thumping (Surge) up to 32 kV with 1000 Joules energy on 8, 16 & 32 kV ranges for pinpointing the fault. 
  • Inbuilt ICM & Decay coupler to connect with Reflectometer for finding distance to the fault. 
  • High voltage metering and mA metering on output.
  • High safety features.

Inbuilt Pressure Testing (Hi-pot Test)
Perform DC high voltage testing up to 32 kV to find out which phase is faulty and determine its breakdown voltage and the leakage current.
Inbuilt Burn down facility
In case of high resistive faults, burning is required. Burning will reduce the breakdown voltage of the fault and it will be easy to pre-locate and pinpoint. Hence, burning facility of more than 240 mA is provided.

Digipoint

  • Magnetic and Acoustic signal strength through bar graph and digits on LCD. 
  • Coincidence figure (Time delay method) indicates the relative distance to the fault in milliseconds (ms) on LCD.
  • LCD screen with backlight feature for night.
  • Background noise reduction and noise immunity.
  • Built to withstand rugged field conditions with high grade acoustic and magnetic sensors.
  • Automatic mute feature to activate while in motion (during pick up of receiver).
  • Easy, fast and accurate pinpointing

Coincidence Figure
Pinpointing the exact location of faults in cables which are laid inside pipe is very difficult because the air inside the pipe will lead to echo of sound which is generated at the fault point, leading to sound/acoustic signal of strength similar to the fault point at different parts of the cable, hence to pinpoint the exact location of fault in these conditions we use the coincidence feature of the Digipoint, which gives the distance to the fault in milliseconds with respect to your position.

Reflectometer T-610

  • Pulse Echo (TDR), Impulse current (ICM) & Decay method provided to get the distance to almost all types of faults.
  • 10” Colour LCD display with user friendly interface for easy operation.
  • Adjustable setting for distance range pulse width, time delay and zoom function.
  • Portable, Microprocessor control, Menu driven, Pulse reflection type, suitable for use in the field.
  • Comparison feature of any 5 graphs for review and analysis to get more accurate results.
  • Velocity of propagation (VOP) control makes it easy to precisely pre-locate faults in cables with different velocity.
  • Automatic storage of more than 100,000 fault graphs.
Request
Callback


Additional Information:

  • Production Capacity: 4 Set per month
  • Delivery Time: Within 4 to 6 Weeks
  • Packaging Details: Wooden Box Packing
Yes! I am Interested

Underground Cable Fault Locator

Underground Cable Fault Locator
  • Underground Cable Fault Locator
  • Underground Cable Fault Locator
  • Underground Cable Fault Locator
  • Underground Cable Fault Locator
  • Underground Cable Fault Locator
  • Underground Cable Fault Locator
  • Underground Cable Fault Locator
  • Underground Cable Fault Locator
  • Underground Cable Fault Locator
  • Underground Cable Fault Locator
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Minimum Order Quantity1 Set
Voltage32 kV
TypeIndustrial Relay
BrandTechno Instrumentation (India) Pvt. Ltd.
Dimension520MM(140MM Handle) X 520MM(130MM Handle) X 730MM(70MM Wheel + 70MM Handle) (LBH) approx.
Model Name/NumberSurGen 32(1000), Digipoint, Reflectometer T-610
Weight Gram120 KG Approx.
Operation Temperature0 Deg. to 55Deg. Celsius
Body MaterialAluminium
Country of OriginMade in India

SurGen 32(1000) 

  • For fault location in LT to HT 11 kV & 33 kV cables.
  • Inbuilt DC high voltage testing up to 32 kV.
  • Inbuilt burn down facility (Burning) suitable for high resistance faults.
  • Output current more than 240 mA.
  • Thumping (Surge) up to 32 kV with 1000 Joules energy on 8, 16 & 32 kV ranges for pinpointing the fault. 
  • Inbuilt ICM & Decay coupler to connect with Reflectometer for finding distance to the fault. 
  • High voltage metering and mA metering on output.
  • High safety features.

Inbuilt Pressure Testing (Hi-pot Test)
Perform DC high voltage testing up to 32 kV to find out which phase is faulty and determine its breakdown voltage and the leakage current.
Inbuilt Burn down facility
In case of high resistive faults, burning is required. Burning will reduce the breakdown voltage of the fault and it will be easy to pre-locate and pinpoint. Hence, burning facility of more than 240 mA is provided.

Digipoint

  • Magnetic and Acoustic signal strength through bar graph and digits on LCD. 
  • Coincidence figure (Time delay method) indicates the relative distance to the fault in milliseconds (ms) on LCD.
  • LCD screen with backlight feature for night.
  • Background noise reduction and noise immunity.
  • Built to withstand rugged field conditions with high grade acoustic and magnetic sensors.
  • Automatic mute feature to activate while in motion (during pick up of receiver).
  • Easy, fast and accurate pinpointing

Coincidence Figure
Pinpointing the exact location of faults in cables which are laid inside pipe is very difficult because the air inside the pipe will lead to echo of sound which is generated at the fault point, leading to sound/acoustic signal of strength similar to the fault point at different parts of the cable, hence to pinpoint the exact location of fault in these conditions we use the coincidence feature of the Digipoint, which gives the distance to the fault in milliseconds with respect to your position.

Reflectometer T-610

  • Pulse Echo (TDR), Impulse current (ICM) & Decay method provided to get the distance to almost all types of faults.
  • 10” Colour LCD display with user friendly interface for easy operation.
  • Adjustable setting for distance range pulse width, time delay and zoom function.
  • Portable, Microprocessor control, Menu driven, Pulse reflection type, suitable for use in the field.
  • Comparison feature of any 5 graphs for review and analysis to get more accurate results.
  • Velocity of propagation (VOP) control makes it easy to precisely pre-locate faults in cables with different velocity.
  • Automatic storage of more than 100,000 fault graphs.
Request
Callback


Additional Information:

  • Item Code: 8543.20.20
  • Production Capacity: 4 Set per month
  • Delivery Time: Within 4 to 6 weeks
  • Packaging Details: Wooden Packing
Yes! I am Interested

Underground Cable Fault Locator Manufacturer From Delhi

Underground Cable Fault Locator Manufacturer From Delhi
  • Underground Cable Fault Locator Manufacturer From Delhi
  • Underground Cable Fault Locator Manufacturer From Delhi
  • Underground Cable Fault Locator Manufacturer From Delhi
  • Underground Cable Fault Locator Manufacturer From Delhi
  • Underground Cable Fault Locator Manufacturer From Delhi
  • Underground Cable Fault Locator Manufacturer From Delhi
  • Underground Cable Fault Locator Manufacturer From Delhi
  • Underground Cable Fault Locator Manufacturer From Delhi
  • Underground Cable Fault Locator Manufacturer From Delhi
  • Underground Cable Fault Locator Manufacturer From Delhi
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Voltage33 kV
BrandTechno Instrumentation (India) Pvt Ltd
Dimension520MM(140MM Handle) X 520MM(130MM Handle) X 730MM(70MM Wheel + 70MM Handle) (LBH) approx.
Model Name/NumberSurGen 32(1000), Digipoint, Reflectometer T-610
Weight Gram120 kg
Operation Temperature0 Degree to 55 Degree C
Body MaterialAluminium
Country of OriginMade in India

SurGen 32(1000) 

  • For fault location in LT to HT 11 kV & 33 kV cables.
  • Inbuilt DC high voltage testing up to 32 kV.
  • Inbuilt burn down facility (Burning) suitable for high resistance faults.
  • Output current more than 240 mA.
  • Thumping (Surge) up to 32 kV with 1000 Joules energy on 8, 16 & 32 kV ranges for pinpointing the fault. 
  • Inbuilt ICM & Decay coupler to connect with Reflectometer for finding distance to the fault. 
  • High voltage metering and mA metering on output.
  • High safety features.

Inbuilt Pressure Testing (Hi-pot Test)
Perform DC high voltage testing up to 32 kV to find out which phase is faulty and determine its breakdown voltage and the leakage current.
Inbuilt Burn down facility
In case of high resistive faults, burning is required. Burning will reduce the breakdown voltage of the fault and it will be easy to pre-locate and pinpoint. Hence, burning facility of more than 240 mA is provided.

Digipoint

  • Magnetic and Acoustic signal strength through bar graph and digits on LCD. 
  • Coincidence figure (Time delay method) indicates the relative distance to the fault in milliseconds (ms) on LCD.
  • LCD screen with backlight feature for night.
  • Background noise reduction and noise immunity.
  • Built to withstand rugged field conditions with high grade acoustic and magnetic sensors.
  • Automatic mute feature to activate while in motion (during pick up of receiver).
  • Easy, fast and accurate pinpointing

Coincidence Figure
Pinpointing the exact location of faults in cables which are laid inside pipe is very difficult because the air inside the pipe will lead to echo of sound which is generated at the fault point, leading to sound/acoustic signal of strength similar to the fault point at different parts of the cable, hence to pinpoint the exact location of fault in these conditions we use the coincidence feature of the Digipoint, which gives the distance to the fault in milliseconds with respect to your position.

Reflectometer T-610

  • Pulse Echo (TDR), Impulse current (ICM) & Decay method provided to get the distance to almost all types of faults.
  • 10” Colour LCD display with user friendly interface for easy operation.
  • Adjustable setting for distance range pulse width, time delay and zoom function.
  • Portable, Microprocessor control, Menu driven, Pulse reflection type, suitable for use in the field.
  • Comparison feature of any 5 graphs for review and analysis to get more accurate results.
  • Velocity of propagation (VOP) control makes it easy to precisely pre-locate faults in cables with different velocity.
  • Automatic storage of more than 100,000 fault graphs.
Request
Callback


Additional Information:

  • Production Capacity: 4 Set per month
  • Delivery Time: Within 4 to 6 Weeks
  • Packaging Details: Wooden Box Packing
Yes! I am Interested

Underground Cable Fault Detector With Distance Locator

Underground Cable Fault Detector With Distance Locator
  • Underground Cable Fault Detector With Distance Locator
  • Underground Cable Fault Detector With Distance Locator
  • Underground Cable Fault Detector With Distance Locator
  • Underground Cable Fault Detector With Distance Locator
  • Underground Cable Fault Detector With Distance Locator
  • Underground Cable Fault Detector With Distance Locator
  • Underground Cable Fault Detector With Distance Locator
  • Underground Cable Fault Detector With Distance Locator
  • Underground Cable Fault Detector With Distance Locator
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Minimum Order Quantity1 Set
Voltage33 kV
BrandTechno Instrumentation (India) Pvt Ltd
Dimension580 x 580 x 780 MM (LWH)
Model Name/NumberSurGen 32(2000), Digipoint, Reflectometer T-610
Operation Temperature0 Degree to 55 Degree C
Weight Gram148 KG Approx.
Body MaterialAluminium
Country of OriginMade in India

SurGen 32(2000) 

  • For fault location in LT to HT 11 kV & 33 kV cables.
  • Inbuilt DC high voltage testing up to 32 kV.
  • Inbuilt burn down facility (Burning) suitable for high resistance faults.
  • Output current more than 335 mA.
  • Thumping (Surge) up to 32 kV with 2000 Joules energy on 8, 16 & 32 kV ranges for pinpointing the fault. 
  • Inbuilt ICM & Decay coupler to connect with Reflectometer for finding distance to the fault. 
  • High voltage metering and mA metering on output.
  • High safety features.

Inbuilt Pressure Testing (Hi-pot Test)
Perform DC high voltage testing up to 32 kV to find out which phase is faulty and determine its breakdown voltage and the leakage current.
Inbuilt Burn down facility
In case of high resistive faults, burning is required. Burning will reduce the breakdown voltage of the fault and it will be easy to pre-locate and pinpoint. Hence, burning facility of more than 350 mA is provided.

Digipoint

  • Magnetic and Acoustic signal strength through bar graph and digits on LCD. 
  • Coincidence figure (Time delay method) indicates the relative distance to the fault in milliseconds (ms) on LCD.
  • LCD screen with backlight feature for night.
  • Background noise reduction and noise immunity.
  • Built to withstand rugged field conditions with high grade acoustic and magnetic sensors.
  • Automatic mute feature to activate while in motion (during pick up of receiver).
  • Easy, fast and accurate pinpointing

Coincidence Figure
Pinpointing the exact location of faults in cables which are laid inside pipe is very difficult because the air inside the pipe will lead to echo of sound which is generated at the fault point, leading to sound/acoustic signal of strength similar to the fault point at different parts of the cable, hence to pinpoint the exact location of fault in these conditions we use the coincidence feature of the Digipoint, which gives the distance to the fault in milliseconds with respect to your position.

Reflectometer T-610

  • Pulse Echo (TDR), Impulse current (ICM) & Decay method provided to get the distance to almost all types of faults.
  • 10” Colour LCD display with user friendly interface for easy operation.
  • Adjustable setting for distance range pulse width, time delay and zoom function.
  • Portable, Microprocessor control, Menu driven, Pulse reflection type, suitable for use in the field.
  • Comparison feature of any 5 graphs for review and analysis to get more accurate results.
  • Velocity of propagation (VOP) control makes it easy to precisely pre-locate faults in cables with different velocity.
  • Automatic storage of more than 100,000 fault graphs.
Request
Callback


Additional Information:

  • Production Capacity: 5 Set per month
  • Delivery Time: Within 4 to 6 Weeks
  • Packaging Details: Wooden Box Packing
Yes! I am Interested

Cable Fault Location Instrument Underground Cable Fault Testing Machine

Cable Fault Location Instrument Underground Cable Fault Testing Machine
  • Cable Fault Location Instrument Underground Cable Fault Testing Machine
  • Cable Fault Location Instrument Underground Cable Fault Testing Machine
  • Cable Fault Location Instrument Underground Cable Fault Testing Machine
  • Cable Fault Location Instrument Underground Cable Fault Testing Machine
  • Cable Fault Location Instrument Underground Cable Fault Testing Machine
  • Cable Fault Location Instrument Underground Cable Fault Testing Machine
  • Cable Fault Location Instrument Underground Cable Fault Testing Machine
  • Cable Fault Location Instrument Underground Cable Fault Testing Machine
  • Cable Fault Location Instrument Underground Cable Fault Testing Machine
  • Cable Fault Location Instrument Underground Cable Fault Testing Machine
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Minimum Order Quantity1 Set
Voltage33 kV
BrandTechno Instrumentation (India) Pvt Ltd
Dimension580 x 580 x 780 MM (LWH)
Model Name/NumberSurGen 32(2000), Digipoint, Reflectometer T-610
Operation Temperature0 Degree to 55 Degree C
Weight Gram148 KG Approx.
Body MaterialAluminium
Country of OriginMade in India

 

SurGen 32(2000) 

  • For fault location in LT to HT 11 kV & 33 kV cables.
  • Inbuilt DC high voltage testing up to 32 kV.
  • Inbuilt burn down facility (Burning) suitable for high resistance faults.
  • Output current more than 350 mA.
  • Thumping (Surge) up to 32 kV with 2000 Joules energy on 8, 16 & 32 kV ranges for pinpointing the fault. 
  • Inbuilt ICM & Decay coupler to connect with Reflectometer for finding distance to the fault. 
  • High voltage metering and mA metering on output.
  • High safety features.

Inbuilt Pressure Testing (Hi-pot Test)
Perform DC high voltage testing up to 32 kV to find out which phase is faulty and determine its breakdown voltage and the leakage current.
Inbuilt Burn down facility
In case of high resistive faults, burning is required. Burning will reduce the breakdown voltage of the fault and it will be easy to pre-locate and pinpoint. Hence, burning facility of more than 350 mA is provided.

Digipoint

  • Magnetic and Acoustic signal strength through bar graph and digits on LCD. 
  • Coincidence figure (Time delay method) indicates the relative distance to the fault in milliseconds (ms) on LCD.
  • LCD screen with backlight feature for night.
  • Background noise reduction and noise immunity.
  • Built to withstand rugged field conditions with high grade acoustic and magnetic sensors.
  • Automatic mute feature to activate while in motion (during pick up of receiver).
  • Easy, fast and accurate pinpointing

Coincidence Figure
Pinpointing the exact location of faults in cables which are laid inside pipe is very difficult because the air inside the pipe will lead to echo of sound which is generated at the fault point, leading to sound/acoustic signal of strength similar to the fault point at different parts of the cable, hence to pinpoint the exact location of fault in these conditions we use the coincidence feature of the Digipoint, which gives the distance to the fault in milliseconds with respect to your position.

Reflectometer T-610

  • Pulse Echo (TDR), Impulse current (ICM) & Decay method provided to get the distance to almost all types of faults.
  • 10” Colour LCD display with user friendly interface for easy operation.
  • Adjustable setting for distance range pulse width, time delay and zoom function.
  • Portable, Microprocessor control, Menu driven, Pulse reflection type, suitable for use in the field.
  • Comparison feature of any 5 graphs for review and analysis to get more accurate results.
  • Velocity of propagation (VOP) control makes it easy to precisely pre-locate faults in cables with different velocity.
  • Automatic storage of more than 100,000 fault graphs.
Request
Callback


Additional Information:

  • Production Capacity: 4 Set per month
  • Delivery Time: Within 4 to 6 Weeks
  • Packaging Details: Wooden Box Packing
Yes! I am Interested

Cable Fault Locator Suppliers, Manufacturers

Cable Fault Locator Suppliers, Manufacturers
  • Cable Fault Locator Suppliers, Manufacturers
  • Cable Fault Locator Suppliers, Manufacturers
  • Cable Fault Locator Suppliers, Manufacturers
  • Cable Fault Locator Suppliers, Manufacturers
  • Cable Fault Locator Suppliers, Manufacturers
  • Cable Fault Locator Suppliers, Manufacturers
  • Cable Fault Locator Suppliers, Manufacturers
  • Cable Fault Locator Suppliers, Manufacturers
  • Cable Fault Locator Suppliers, Manufacturers
  • Cable Fault Locator Suppliers, Manufacturers
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Minimum Order Quantity1 Set
Voltage11 kV
BrandTechno Instrumentation (India) Pvt Ltd
Dimension580x 580 x 780 MM (LWH)
Model Name/NumberSurGen 16(R1000), Digipoint, Reflectometer T-710
Operation Temperature0 Degree to 55 Degree C
Weight Gram135 KG Approx.
Body MaterialAluminium
Country of OriginMade in India

SurGen 16(R1000) 

  • For fault location in LT to HT 11 kV cables.
  • Inbuilt DC high voltage testing up to 16 kV.
  • Inbuilt burn down facility (Burning) suitable for high resistance faults.
  • Output current more than 250 mA.
  • Thumping (Surge) up to 16 kV with 1000 Joules energy on 4, 8 & 16 kV ranges for pinpointing the fault. 
  • Inbuilt ARC Reflection filter, ICM & Decay coupler to connect with Reflectometer for finding distance to the fault.
  • High voltage metering and mA metering on output.
  • High safety features.

Inbuilt Pressure Testing (Hi-pot Test)
Perform DC high voltage testing up to 16 kV to find out which phase is faulty and determine its breakdown voltage and the leakage current.
Inbuilt Burn down facility
In case of high resistive faults, burning is required. Burning will reduce the breakdown voltage of the fault and it will be easy to pre-locate and pinpoint. Hence, burning facility of more than 250 mA is provided.

Digipoint

  • Magnetic and Acoustic signal strength through bar graph and digits on LCD. 
  • Coincidence figure (Time delay method) indicates the relative distance to the fault in milliseconds (ms) on LCD.
  • LCD screen with backlight feature for night.
  • Background noise reduction and noise immunity.
  • Built to withstand rugged field conditions with high grade acoustic and magnetic sensors.
  • Automatic mute feature to activate while in motion (during pick up of receiver).
  • Easy, fast and accurate pinpointing

Coincidence Figure
Pinpointing the exact location of faults in cables which are laid inside pipe is very difficult because the air inside the pipe will lead to echo of sound which is generated at the fault point, leading to sound/acoustic signal of strength similar to the fault point at different parts of the cable, hence to pinpoint the exact location of fault in these conditions we use the coincidence feature of the Digipoint, which gives the distance to the fault in milliseconds with respect to your position.


Reflectometer T-710

  • Pulse Echo (TDR), Impulse current (ICM), ARC Reflection & Decay method provided to get the distance to almost all types of faults.
  • 10” Colour LCD display with user friendly interface for easy operation.
  • Adjustable setting for distance range pulse width, time delay and zoom function.
  • Portable, Microprocessor control, Menu driven, Pulse reflection type, suitable for use in the field.
  • Comparison feature of any 5 graphs for review and analysis to get more accurate results.
  • Automatic storage of more than 100,000 fault graphs.
  • Rechargeable battery with 230V AC + 10%, 50Hz, Charger.
Request
Callback


Additional Information:

  • Production Capacity: 4 Set per month
  • Delivery Time: 4 to 6 Weeks
  • Packaging Details: Wooden Box Packing
Yes! I am Interested
X

Explore More Products

View All Products




Reach Us
Mr. Ravi Gupta (Director)
Techno Instrumentation (India) Pvt. Ltd.
Plot No. 67, Street No. 1B, Friends Colony, Industrial Area, G. T. Road, Shahdara
Delhi - 110095, India


Call Us


Send E-mail